Preflight and Convert run the same checks. A failed check stops the conversion; a warning lets it go on.

MessageWhat to do
No sceneOpen a model first, see Opening models.
No attribute spreadsheet · geometry onlyA warning only. Convert then offers Convert geometry only or Make template spreadsheet, see Your first conversion.
Mapping not found, Mapping unreadable or Not a mapping · no join keyClick Build under Mapping and finish the mapping again.
No join keySet Join key in the mapping window, see Map the spreadsheet columns.
Mapped columns not in spreadsheetThe mapping was made for another spreadsheet, or a column was renamed. Build the mapping again.
Duplicate headersTwo columns have the same name. Rename one in the spreadsheet.
Duplicate join keysAn object name appears on more than one row. The later rows are skipped.
Not a numberA number column holds text. Those cells go out as -.
Dates not ISO 8601Write dates as 2027-03-11.
IDs stored as numbersThe spreadsheet keeps an ID column as numbers, so leading zeros are lost. Format the column as text, so 0012 stays 0012.
JoinedShows how many objects found a row, see Check the join.
No target layerTurn on Include in output for at least one layer.
Empty layersA layer in the output has no objects.
CRSThe CRS does not fit the coordinates. Check it, see Set the coordinate system.
No output folder, Cannot create folder or Folder not writableChoose another folder under Location · name.
Invalid characters in file name or File name ends with dot or spaceChange Name under Location · name.
File in use or read-onlyAn output file with the same name is open in another program. Close it and convert again.